- 4G FC-to-FC RAID controller head
- Twelve (12) 4G FC SFP ports
- SAS (Serial Attached SCSI) wide links to drive enclosures (as backup or less-frequently accessed volumes)
- Fault-tolerant connection points to DAS or switched fabric
- Hardware RAID6 engine by dedicated ASIC400 chipsets
- Redundant-/single-RAID controller configurations
- Dedicated SATA RCC (Redundant Controller Communications) channels
- Corresponding drive enclosures:
- F16F-J4000-R loop-switched SBODs
- S16S-J1000-R/S JBODs (using SATA-II 3Gbps drives)
|
 |
|
 |
| |
|
|
|
|
|
|
|
|
|
|
12 |
12 |
2 |
4G FC-to-FC/SATA-II |
|
Single controller |
1U Rackmount |
12 |
6 |
1 |
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
- Hardware RAID engine
- Supports RAID 0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60, and NRAID
- RAID Migration
- Configurable stripe size and write policy per array
- Multiple Global, Dedicated, & Enclosure-specific hot-spares
- Intelligent Drive Handling:
- In degraded mode: skips irreparable blocks to continue rebuild
- In normal operation: data-block verification and repair
|
|
| |
|
|
|
|
| |
- Compact 1U enclosure
- Dual-active/Single- RAID controller configurations
- Fault-tolerant modules interfaced through a common backplane
- One (1) 512MB DDR DIMM per controller (default, supports up to 2GB in size)
- Redundant, hot-swappable 250W power supply units
- Redundant, dual-speed cooling modules
- Hot-swappable I/O modules
- LCD keypad panel
- Li-Ion battery backup unit (BBU), life expectancy and charge level aware
|
|
| |
|
|
|
|
| |
- Four (4) out of the six (6) 4G FC channels per controller
- 32Gbps bandwidth via separate host ports from individual controllers
- Hot-swappable I/O modules
- Concurrent I/O commands
- Tagged command queuing up to 1024
- Max. command queue up to 1024
- Fault-tolerant host links via external FC switches or the onboard hub
|
|
| |
|
|
|
|
| |
- Two (2 - default) or four (4 - manual) in dual-loops to F16F series FC drive enclosures
- Two (2 - R4030) or one (1 - S4030) SAS ports (SFF-8470) to S16S series drive enclosures (using SATA-II disk drives)
- S.M.A.R.T. support
- Automatic bad-sector reassignment
- Intelligent loop switched access fairness dual-loop
- SES enclosure service support through the drive loops
|
|
| |
|
|
|
|
| |
- COM1 serial port for local access to firmware-embedded utility
- COM2 for UPS connection
- GUI, Telnet, and SSH system access via an Ethernet port
- Browser-based or Java-based RAIDWatch manager software
- Management of multiple enclosures via RAID firmware and/or through GUI
- Firmware-embedded manager via RS-232C (audio jack) that is platform independent
- Widest range of event notification methods including email, LAN broadcast, fax, SNMP traps, SMS, and MSN
- LCD keypad panel to all configuration options
- Variable logical drive options per DIMM size
- Module status LED indicators:
- Seven (7) per controller module
- One (1) per power supply unit
- One (1) per BBU module
- Two (2) per cooling module
- Three (3) per LCD panel
- Two (2) per Ethernet port
- Two (2) per Fibre port on I/O module
- Presence detect & thermal sensors via I²C bus (via SES with drive enclosures)
|
|
| |
|
| |
|
| |
- Twelve (12) Fibre SFP ports on individual I/O modules, with onboard hub
- Two (2 - R4030) or one (1 - S4030) SAS wide ports (SFF-8470 Infiniband type)
- One (1) Fast Ethernet management port (per controller)
- Two (2) serial COM ports (per controller)
|
|
| |
|
| |
Redundant hot-swappable power supplies with PFC |
|
| |
|
100VAC at 5A, 240VAC at 2.5A with PFC (auto-switching) |
47 to 63Hz |
|
(Maximum output: 250 Watts) |
+12.0V |
16A max. |
+ 5.0V |
25A max. |
| + 3.3V |
20A max. |
|
|
| |
Cooling Module |
|
| |
Redundant dual-thermal-fan cooling modules |
|
| |
|
High speed: 31.8 CFM
Low speed: 20.1 CFM |
|
|
| |
Environmental Specifications |
|
| |
Operating: 0° to 40°C (32° F to 104° F) (without BBU)
Operating: 0° to 35°C (32° F to 95° F) (with BBU)
Non-operating: - 40° to 60°C (-40° F to 140° F) |
5% to 95% (non condensing - operating and non-operating) |
Operating: sea level to 12,000 ft
Non-operating: sea level to 40,000 ft |
|
|
| |
Dimensions |
|
| |
- 43.5mm(H) x 442mm(W) x 540mm(L) (1.7 x 17.4 x 21.3 inches)
- Package: 18(H) x 59(W) x 72(D) cm (7.1 x 23.2 x 28.3 inches)
|
|
| |
|
| |
- Net weight: 10kg (22 pounds)
- Gross weight: 11.5kg (25.3 pounds)
|
|
| |
 |
|
| |
Return to Top |
|
| |
|
|
|
|
|