1-866-948-DATA (3282)

>        
           
  S12S-R1032                                                        |    Specifications    |    Accessories    |    Datasheet  
           
   
  • SAS to SAS/SATA-II RAID subsystem
  • Redundant RAID controller
  • EonPath multi-pathing, load-balancing software
  • 4 SAS 4x wide host ports
  • Hardware RAID6 engine by dedicated ASIC400 chipsets
  • Superior performance w/ uncomplicated connectivity
  • 12 SAS or SATA-II disk drives
  • Expansion to 48TB via 4x wide expansion port
  • Corresponding JBODs:
    S12S-J1002-R (dual-controller)
See details about expansion enclosures:
S12S-J1002-R (dual-controller)
 
           
Model
Host Interface
Drive Interface SAS Exp.
Controller
Form Factor
S12S-R1032
4 multi-lane wide ports (SFF-8088)
SAS / SATA-II
2 wide ports
(SFF-8088)
Dual redundant
2U Rackmount
 
 

Corresponding JBODs

   
 
RAID
JBOD
Max Number
S12S-R1032
S12S-J1002-R
3
 
  Specifications        
  RAID        
 
  • Hardware RAID5 & RAID6
  • Supports RAID 0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60, NRAID, and JBOD
  • RAID Migration
  • Configurable stripe size and write policy per array
  • Multiple Global, Dedicated, & Enclosure-specific hot-spares
  • Intelligent Drive Handling:
    • In degraded mode: skips irreparable blocks to continue rebuild
    • In normal operation: data-block verification and repair
 
  System Components        
 
  • High density, smartly managed 2U enclosure
  • Dual redundant RAID controller
  • One DIMM module with capacities from 512MB to 2GB
  • Redundant, hot-swappable 530W power supply units
  • Redundant, dual-speed cooling modules 
  • Twelve (12), hot-swappable drive trays
  • Two (2) forearm handles
  • Li-Ion battery backup unit (BBU), life expectancy and charge level aware
 
  Host Interface        
 
  • 4 SAS wide ports
  • 12Gbps bandwidth (half duplex) per port
  • Concurrent I/O commands
  • Tagged command queuing up to 1024
  • Max. command queue up to 1024
  • Fault-tolerant host links with the EonPath multi-pathing software
  • Included cables:
    • S12S-R1032 - 2x Mini-SAS-to-Mini-SAS SFF-8088 120cm cables
 
  Drive Interface        
 
  • 12 3.0Gbps SAS/SATA-II, hot-swappable drive trays
  • Accommodates 1-inch pitch, 3.5-inch SAS or SATA-II (3Gbps) disk drives
  • S.M.A.R.T. and NCQ support
  • Automatic bad-sector reassignment
  • Dedicated bandwidth to each connected drive
  • In-band enclosure service through the expansion links from expansion enclosures
  • Path redundancy to disk drives via edge expanders and expanders on JBOD controllers through separate SAS domains
  • MUX kits with port selectors for dual-controller access to SATA drives
 
  Management        
 
  • COM1 serial port for local access to firmware-embedded utility
  • COM2 for UPS connection
  • Automated cache flush and caching mode operation per enclosure status
  • GUI, Telnet, and SSH system monitoring via Ethernet
  • Browser-based or Java-based RAIDWatch manager software
  • Firmware-embedded manager via RS-232C (audio jack) that is platform independent
  • Widest range of event notification methods including email, LAN broadcast, fax, SNMP traps, SMS, and MSN
  • LCD keypad panel for monitoring and access to all configuration options
  • Variable logical drive options per DIMM size
  • Module status LED indicators:
    • Two (2) per drive tray
    • Seven (7) per controller module
    • One (1) per power supply unit
    • One (1) per BBU module
    • Two (2) per cooling module
  • Presence detection & thermal sensors via I²C bus
 
  Physical/Electrical  
  Power Supply Module  
  Two (2) redundant, hot-swappable power supplies with PFC  
 
Input
  100VAC at 10A, 240VAC at 5A with PFC (auto-switching)
   47 to 63Hz
Output
  Maximum output: 530 Watts
  + 12.0V
  43A max.
  + 5.0V
  25A max.
 
  Cooling Module  
  Two (2) dual-fan cooling modules  
 
Maximum Air Flow
90CFM (high speed); 70.7CFM (low speed)
 
  Environmental Specifications  
 
Temperature Operating: 5° to 40°C (35°C if battery is applied)
Non-operating: - 40° to 60°C (-40° F to 140° F)
Relative Humidity
5% to 95% (non condensing - operating and non-operating)
Altitude
Operating: 3,658m (12,000 ft.)
Non-operating: 12,192m (40,000 ft.)
 
  Dimensions  
 
  • Chassis without handles: 446(W) x 88(H) x 498(D) mm (17.56W x 3.46H x 19.6D inches)
  • Chassis with handles: 482 (W) x 88(H) x 516(D) mm (18.97W x 3.46H x 20.31D inches)
  • Package: 575W x 390H x 780D mm (22.63W x 15.35H x 30.7D inches)
 
  System weight  
 
  • S12S-R1032: Net weight - 18.71kg (41.16 pounds), Gross weight - 25.9kg (56.98 pounds)
 
   
  Return to Top