- SAS to SAS/SATA-II RAID subsystem
- Redundant RAID controller
- EonPath multi-pathing, load-balancing software
- 4 SAS 4x wide host ports
- Hardware RAID6 engine by dedicated ASIC400 chipsets
- Superior performance w/ uncomplicated connectivity
- 12 SAS or SATA-II disk drives
- Expansion to 48TB via 4x wide expansion port
- Corresponding JBODs:
S12S-J1002-R (dual-controller)
See details about expansion enclosures:
S12S-J1002-R (dual-controller) |
 |
|
 |
| |
|
|
|
|
|
|
| S12S-R1032 |
4 multi-lane wide ports (SFF-8088)
|
SAS / SATA-II |
|
|
2U Rackmount |
|
|
| |
|
|
|
| |
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
- Hardware RAID5 & RAID6
- Supports RAID 0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60, NRAID, and JBOD
- RAID Migration
- Configurable stripe size and write policy per array
- Multiple Global, Dedicated, & Enclosure-specific hot-spares
- Intelligent Drive Handling:
- In degraded mode: skips irreparable blocks to continue rebuild
- In normal operation: data-block verification and repair
|
|
| |
|
|
|
|
| |
-
- High density, smartly managed 2U enclosure
- Dual redundant RAID controller
- One DIMM module with capacities from 512MB to 2GB
- Redundant, hot-swappable 530W power supply units
- Redundant, dual-speed cooling modules
- Twelve (12), hot-swappable drive trays
- Two (2) forearm handles
- Li-Ion battery backup unit (BBU), life expectancy and charge level aware
|
|
| |
|
|
|
|
| |
- 4 SAS wide ports
- 12Gbps bandwidth (half duplex) per port
- Concurrent I/O commands
- Tagged command queuing up to 1024
- Max. command queue up to 1024
- Fault-tolerant host links with the EonPath multi-pathing software
- Included cables:
- S12S-R1032 - 2x Mini-SAS-to-Mini-SAS SFF-8088 120cm cables
|
|
| |
|
|
|
|
| |
- 12 3.0Gbps SAS/SATA-II, hot-swappable drive trays
- Accommodates 1-inch pitch, 3.5-inch SAS or SATA-II (3Gbps) disk drives
- S.M.A.R.T. and NCQ support
- Automatic bad-sector reassignment
- Dedicated bandwidth to each connected drive
- In-band enclosure service through the expansion links from expansion enclosures
- Path redundancy to disk drives via edge expanders and expanders on JBOD controllers through separate SAS domains
- MUX kits with port selectors for dual-controller access to SATA drives
|
|
| |
|
|
|
|
| |
- COM1 serial port for local access to firmware-embedded utility
- COM2 for UPS connection
- Automated cache flush and caching mode operation per enclosure status
- GUI, Telnet, and SSH system monitoring via Ethernet
- Browser-based or Java-based RAIDWatch manager software
- Firmware-embedded manager via RS-232C (audio jack) that is platform independent
- Widest range of event notification methods including email, LAN broadcast, fax, SNMP traps, SMS, and MSN
- LCD keypad panel for monitoring and access to all configuration options
- Variable logical drive options per DIMM size
- Module status LED indicators:
- Two (2) per drive tray
- Seven (7) per controller module
- One (1) per power supply unit
- One (1) per BBU module
- Two (2) per cooling module
- Presence detection & thermal sensors via I²C bus
|
|
| |
|
| |
|
| |
Two (2) redundant, hot-swappable power supplies with PFC |
|
| |
|
100VAC at 10A, 240VAC at 5A with PFC (auto-switching)
|
47 to 63Hz |
|
Maximum output: 530 Watts |
+ 12.0V |
43A max. |
+ 5.0V |
25A max. |
|
|
| |
|
| |
Two (2) dual-fan cooling modules |
|
| |
|
90CFM (high speed); 70.7CFM (low speed) |
|
|
| |
|
| |
Operating: 5° to 40°C (35°C if battery is applied)
Non-operating: - 40° to 60°C (-40° F to 140° F) |
5% to 95% (non condensing - operating and non-operating) |
Operating: 3,658m (12,000 ft.)
Non-operating: 12,192m (40,000 ft.)
|
|
|
| |
|
| |
- Chassis without handles: 446(W) x 88(H) x 498(D) mm (17.56W x 3.46H x 19.6D inches)
- Chassis with handles: 482 (W) x 88(H) x 516(D) mm (18.97W x 3.46H x 20.31D inches)
- Package: 575W x 390H x 780D mm (22.63W x 15.35H x 30.7D inches)
|
|
| |
|
| |
- S12S-R1032: Net weight - 18.71kg (41.16 pounds), Gross weight - 25.9kg (56.98 pounds)
|
|
| |
 |
|
| |
Return to Top |
|
| |
|
|